大家好
我试图启动IntelligentEdgeHOL项目
因此,我遵循github上的自述文件命令sudo service iotedge restart
不seam work,因为下一个命令journalctl -u iotedge --no-pager --no-full
返回我:
<pre>-- Logs begin at Thu 2021-02-25 14:20:00 CET, end at Thu 2021-02-25 15:40:49 CET. --
févr. 25 14:20:08 procomm-desktop systemd[1]: Started Azure IoT Edge daemon.
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Starting Azure IoT Edge Security Daemon
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Version - 1.1.0
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Using config file: /etc/iotedge/config.yaml
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Configuring /var/lib/iotedge as the home directory.
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Configuring certificates...
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Transparent gateway certificates not found, operating in quick start mode...
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Finished configuring provisioning environment variables and certificates.
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Initializing hsm...
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Finished initializing hsm.
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Provisioning edge device...
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] - Starting provisioning edge device via manual mode using a device connection string...
févr. 25 14:20:08 procomm-desktop iotedged[7064]: <font color="#EF2929"><b>2021-02-25T13:20:08Z [ERR!] - The daemon could not start up successfully: Could not load settings</b></font>
févr. 25 14:20:08 procomm-desktop iotedged[7064]: <font color="#EF2929"><b>2021-02-25T13:20:08Z [ERR!] - caused by: The Connection String is missing required parameter SharedAccessKey</b></font>
févr. 25 14:20:08 procomm-desktop iotedged[7064]: 2021-02-25T13:20:08Z [INFO] (/project/edgelet/hsm-sys/azure-iot-hsm-c/src/hsm_log.c:log_init:41) Initialized logging
févr. 25 14:20:08 procomm-desktop systemd[1]: <b>iotedge.service: Main process exited, code=exited, status=153/n/a</b>
févr. 25 14:20:08 procomm-desktop systemd[1]: <b>iotedge.service: Failed with result 'exit-code'.</b>
févr. 25 15:40:01 procomm-desktop systemd[1]: Started Azure IoT Edge daemon.
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Starting Azure IoT Edge Security Daemon
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Version - 1.1.0
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Using config file: /etc/iotedge/config.yaml
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Configuring /var/lib/iotedge as the home directory.
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Configuring certificates...
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Transparent gateway certificates not found, operating in quick start mode...
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Finished configuring provisioning environment variables and certificates.
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Initializing hsm...
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Finished initializing hsm.
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Provisioning edge device...
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] - Starting provisioning edge device via manual mode using a device connection string...
févr. 25 15:40:01 procomm-desktop iotedged[24011]: <font color="#EF2929"><b>2021-02-25T14:40:01Z [ERR!] - The daemon could not start up successfully: Could not load settings</b></font>
févr. 25 15:40:01 procomm-desktop iotedged[24011]: <font color="#EF2929"><b>2021-02-25T14:40:01Z [ERR!] - caused by: The Connection String is missing required parameter SharedAccessKey</b></font>
févr. 25 15:40:01 procomm-desktop iotedged[24011]: 2021-02-25T14:40:01Z [INFO] (/project/edgelet/hsm-sys/azure-iot-hsm-c/src/hsm_log.c:log_init:41) Initialized logging
févr. 25 15:40:01 procomm-desktop systemd[1]: <b>iotedge.service: Main process exited, code=exited, status=153/n/a</b>
févr. 25 15:40:01 procomm-desktop systemd[1]: <b>iotedge.service: Failed with result 'exit-code'.</b>
</pre>
有人知道我应该将丢失的SharedAccessKey参数放入哪个配置文件吗
目前没有回答
相关问题 更多 >