我有一个带有两个简单按钮的小GUI来访问LabJAck IO模块。此模块用于打开或关闭与其相连的外部设备。我写了一个初始化设备的类和几个方法来处理设备的一些事情,其中两个是,打开和关闭。我之所以要用这种方式访问LAbJack是因为我希望代码是好的和整洁的,我将有几个设备连接到我的机器上,每个设备都有特定的IO命令。在
这是我的LabJAck代码:
import u3
class LabJack:
def __init__(self):
try:
self.Switch = u3.U3()
except:
print "Labjack Error"
#Define State Registers for RB12 Relay Card
self.Chan0 = 6008
Chan1 = 6009
Chan2 = 6010
Chan3 = 6011
Chan4 = 6012
Chan5 = 6013
#Turn the channel on
def IO_On(self,Channel):
self.Switch.writeRegister(Channel,0)
#Turn the channel off
def IO_Off(self,Channel):
self.Switch.writeRegister(Channel,1)
#The State of the Channel
def StateSetting(self,Channel):
self.Switch.readRegister(Channel)
if Switch.readRegister(Channel) == 0:
print ('Channel is On')
else:
print('Channel is Off')
#Direction of Current Flow
def CurrentDirection(self,Channel):
self.Switch.readRegister(6108)
print self.Switch.readRegister(6108)
下面是我的GUI代码:
^{pr2}$运行代码时,我得到以下错误:
Traceback (most recent call last):
File "ALDSoftwareMainWindow.py", line 26, in <module>
form = ALDMainWindow()
File "ALDSoftwareMainWindow.py", line 20, in __init__
self.Valve_ON.clicked.connect(self.ValveControl.IO_On(6008))
TypeError: connect() slot argument should be a callable or a signal, not 'int'
我不知道我做错了什么。任何帮助都将不胜感激。在
谢谢。在
您正在调用将按钮连接到的方法:
这可能会解决您的问题:
^{pr2}$lambda
是一个匿名函数,它将延迟对方法IO_ON(6008)
的调用,直到实际单击按钮为止。在你对插槽/信号的工作原理有错误的理解。
connect
的参数必须是一个函数,该函数接受所连接到的信号发出的任何信号。在本例中,看起来您是从一个按钮连接到clicked
信号(它不发出值)。因此,您需要将要调用的函数包装在一个不带参数的函数中。一种简单的方法是将函数包装在lambda
函数中:它创建带有一个可选参数(默认值为所需值)的函数,因此它将作为无参数槽使用。在
使用默认参数将值绑定到中似乎有些奇怪,但它可以防止闭包出现一些奇怪的问题(请参见Python lambda closure scoping)
另一种方法是使用^{} 包装函数。在
1使用
partial
可能是最好的方法。在2使用
QSignalMapper